Coding <Channel type>:
hex 0 Empty channel (EM)
hex 2 Arithmetic channel (AR)
hex 3 Digital output channel (DO)
hex 4 Digital input channel (DI)
hex 5 Setpoint channel (VO)
hex 6 Alarm channel (AL)
Coding < Measuring principle >:
Digital Input:
hex 0 No input
hex 1 Host input
hex 2 Frequency
hex 3 Progressive counter
hex 7 Interval counter
Digital Output:
hex 0 No output
hex 1 Host output
hex 3 Process output
Coding <Reset, storage>:
hex 0 No reset, no storage of channels
hex 1 Reset valid, no storage of channels
hex 2 No reset, storage of channels enabled
hex 3 Reset valid, storage of channels enabled